MAX30100 MAX30102 Herzfrequenz Hämoglobin Sensor

3,92 4,79 

MAX30100 MAX30102 Herzfrequenz

Lieferzeit: sofort

Beschreibung

MAX30100 MAX30102 Herzfrequenz Heart Rate Blut Sauerstoff Oxy- Desoxy- Hämoglobin Sensor Modul

3.3V-5V MAX3010X Heart Rate Blood oxygen concentration Sensor Module © androegg

MAX30100 Heart Rate Blood oxygen concentration Sensor Module incl. Pinheader © androegg

MAX30102 Heart Rate Blood oxygen concentration Sensor Module incl. Pinheader © androegg

MAX3010X Heart Rate Blood oxygen concentration Sensor Module © androegg

MAX3010X 3,3V-5V Herzfrequenz- Blutsauerstoff (Oxy- Desoxy- Hämoglobin) Sensor Modul wie folgt verfügbar:

  • MAX30100 Sensor Modul mit einer 14 bits ADC Auflösung
  • MAX3102 Sensor Modul mit einer 18 bits ADC Auflösung

 

Die MAX3010x-Sensoren sind Pulsoximetersensoren aus dem Hause Maxim Integrated. Beide Sensoren verfügen über eine rote und eine IR-LED sowie eine Fotodiode zur Bestimmung der reflektierten Lichtmenge. Die Sensoren sind für die Photoplethysmographie (PPG), auch bekannt als optische Herzfrequenzmessung bzw. Pulsoximetrie Sättigungssensorik.

Das grundlegende Funktionsprinzip ist das gleiche wie bei typischen / einfachen Modulen zur Bestimmung der Herzfrequenz. Bei dem hier kombinierten Messverfahren wird stets nur eine der 2 LED aktiviert. Demenstprechend wird stets zwischen 2 Spektren

  • roter (LED) visueller Strahlung
    und
  • infrarot (LED) IR Strahlung

differenziert.

Oxygeniertes und desoxygeniertes Hämoglobin haben eine leicht differenzierte Molekularstruktur und weisen somit ein abweichendes Absorptionsspektrum vor. Mit Sauerstoff angereichertes Hämoglobin absorbiert IR-Licht stärker als rotes Licht, während sauerstoffarmes Hämoglobin rotes Licht besser als IR-Licht absorbiert.

Durch Vergleich der Menge des jeweilig absorbierten Lichts für die rote und die IR-LED ist es möglich, die Sauerstoffsättigung differenziert zu bestimmen.

Die Signalausgabe des MAX3010X Modul erfolgt über die I2C Schnittstelle.

MAX3010X 3.3V-5V Heart Rate Blood oxygen concentration (hemoglobin becomes deoxygenated) Sensor Module available in 2 Versions:

  • MAX30100 Sensor Module with 14 bits ADC Resolution
  • MAX30102 Sensor Module with 18 bits ADC Resolution

 

The MAX3010x sensors are pulse oximeter sensors from Maxim Integrated. Both sensors have a red and an IR LED as well as a photodiode to determine the amount of reflected light. The sensors are for photoplethysmography (PPG), also known as optical heart rate measurement or pulse oximetry saturation sensors.

The basic principle of operation is the same as typical/simple heart rate modules. With the measuring method combined here, only one of the 2 LEDs is activated. Accordingly, it is always between 2 spectra

  • red (LED) visual radiation
    and
  • infrared (LED) IR radiation

differentiated.

Oxygenated and deoxygenated hemoglobin have a slightly different molecular structure and thus have a different absorption spectrum. Oxygenated hemoglobin absorbs IR light more than red light, while deoxygenated hemoglobin absorbs red light better than IR light. By comparing the amount of light absorbed by the red and IR LEDs, it is possible to determine the oxygen saturation in a differentiated manner.

The signal output of the MAX3010X module is based on I2C protocol.

MAX31100 Module features:

  • Supply Voltage: 3.3 – 5 Volt
  • current consumption: max. 20mA (continous output)
  • ADC Resolution: 14 bits
    • Red ADC Count 23,000 – 29,000 Counts
    • IR ADC Count 23,000 – 29,000 Counts
  • Interface: I2C
    • 3.3V Level
    • Serial Clock Frequency 0-400 kHz
    • Write Address AE (hex)
    • Read Address AF (hex)
  • LED Wavelength:
    • IR LED 870 – 900nm (880nm peak)
    • Red LED 650 – 670nm (660nm peak)
  • Temperature Sensor:
    • Temperature ADC Acquisition Time @ +25°C 29 ms
    • Temperature Sensor Accuracy @ +25°C ±1 °C
    • Temperature Sensor Minimum Range TMIN -40 °C
    • Temperature Sensor Maximum Range TMAX 85 °C
  • Dimensions: 14 x 14 mm

 

MAX31102 Module features:

  • Supply Voltage: 3.3 – 5 Volt
  • current consumption: max. 20mA (continous output)
  • ADC Resolution: 18 bits
    • Red ADC Count 65563 Counts
    • IR ADC Count 65563 Counts
  • Interface: I2C
    • 3.3V Level
    • Serial Clock Frequency 0-400 kHz
    • Write Address AE (hex)
    • Read Address AF (hex)
  • LED Wavelength:
    • IR LED 870 – 900nm (880nm peak)
    • Red LED 650 – 670nm (660nm peak)
  • Temperature Sensor:
    • Temperature ADC Acquisition Time @ +25°C 29 ms
    • Temperature Sensor Accuracy @ +25°C ±1 °C
    • Temperature Sensor Minimum Range TMIN -40 °C
    • Temperature Sensor Maximum Range TMAX 85 °C
  • Dimensions: 14 x 14 mm

 

Zusätzliche Informationen

Version

MAX30102 + Pins, MAX30100 + Pins

Das könnte dir auch gefallen …

Anmelden